天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產(chǎn)品中心

小鼠CCAAT增強子結合蛋白α(CEBPa)酶聯(lián)免疫吸附檢測試劑盒
ELK9508
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻

Product name: Mouse CEBPa(CCAAT/Enhancer Binding Protein Alpha) ELISA Kit
Reactivity: Mouse
Alternative Names: CEBP-A
Assay Type: Sandwich
Sensitivity: 0.066 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: Tissue homogenates, cell lysates and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;Metabolic pathway;Cardiovascular biology;
Uniprot ID: P53566
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse CEBPa. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse CEBPa. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse CEBPa, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse CEBPa in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
10.00 2.266 2.184
5.00 1.528 1.446
2.50 1.228 1.146
1.25 0.864 0.782
0.63 0.539 0.457
0.32 0.356 0.274
0.16 0.235 0.153
0.00 0.082 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CEBPa and the recovery rates were calculated by comparing the measured value to the expected amount of CEBPa in samples.
Matrix Recovery range Average
serum(n=5) 82-94% 88%
EDTA plasma(n=5) 90-103% 96%
Heparin plasma(n=5) 95-107% 101%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CEBPa and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-96% 93-101% 82-94% 86-96%
EDTA plasma(n=5) 81-97% 92-105% 83-92% 85-92%
Heparin plasma(n=5) 87-97% 96-105% 92-103% 82-96%
關閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術支持

關注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關閉
托克逊县| 临汾市| 安阳市| 同德县| 黑龙江省| 德阳市| 唐海县| 即墨市| 仪陇县| 崇信县| 涿鹿县| 通州市| 沁阳市| 治县。| 连州市| 佛冈县| 汉川市| 汝阳县| 增城市| 麻城市| 安远县| 余姚市| 辽中县| 大化| 额敏县| 边坝县| 呈贡县| 新宁县| 遂平县| 双鸭山市| 延寿县| 巍山| 台中市| 仙桃市| 安达市| 布尔津县| 县级市| 合肥市| 大兴区| 万州区| 龙井市|