天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產(chǎn)品中心

人可溶性白介素30(sIL30)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK9351
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻(xiàn)

Product name: Human sIL30(Soluble Interleukin 30) ELISA Kit
Reactivity: Human
Alternative Names: IL-27;p28; IL30; Interleukin 30; Interleukin-27 subunit alpha
Assay Type: Sandwich
Sensitivity: 3 pg/mL
Standard: 500 pg/mL
Detection Range: 7.82-500 pg/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids.
Assay Length: 3.5h
Research Area: Cytokine;Tumor immunity;Infection immunity;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human sIL30. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human sIL30. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human sIL30, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human sIL30 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線(xiàn)

Concentration (pg/mL) OD Corrected OD
500.00 2.154 2.069
250.00 1.585 1.500
125.00 1.115 1.030
62.50 0.861 0.776
31.25 0.548 0.463
15.63 0.305 0.220
7.82 0.252 0.167
0.00 0.085 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant sIL30 and the recovery rates were calculated by comparing the measured value to the expected amount of sIL30 in samples.
Matrix Recovery range Average
serum(n=5) 81-95% 88%
EDTA plasma(n=5) 90-107% 98%
Heparin plasma(n=5) 87-99% 93%

線(xiàn)性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of sIL30 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 96-105% 93-101% 79-96% 92-105%
EDTA plasma(n=5) 91-99% 85-102% 79-92% 87-103%
Heparin plasma(n=5) 89-98% 80-101% 83-97% 95-104%
關(guān)閉

在線(xiàn)咨詢(xún)

Online consultation

  • 在線(xiàn)咨詢(xún)
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢(xún)

微信掃一掃立即咨詢(xún)

關(guān)閉
边坝县| 石泉县| 肥西县| 大石桥市| 墨江| 浪卡子县| 康马县| 宜宾县| 栾川县| 新沂市| 西丰县| 拉萨市| 昌乐县| 托里县| 峡江县| 山东| 平武县| 胶州市| 微博| 罗山县| 银川市| 明光市| 松原市| 蒲江县| 玉屏| 响水县| 青海省| 同江市| 永善县| 灵石县| 醴陵市| 渭南市| 遵化市| 呼和浩特市| 花垣县| 凯里市| 崇信县| 分宜县| 儋州市| 新津县| 凤山县|