天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產(chǎn)品中心

小鼠沉默調(diào)節(jié)蛋白1(SIRT1)酶聯(lián)免疫吸附檢測試劑盒
ELK6397
規(guī)格: 價格:
48T ¥2240.00
96T ¥3200.00

Overview 文獻(xiàn)

Product name: Mouse SIRT1(Sirtuin 1) ELISA Kit
Reactivity: Mouse
Alternative Names: SIR2L1; Silent Mating Type Information Regulation 2 Homolog 1; NAD-Dependent Deacetylase Sirtuin-1; SIR2-like protein 1; SirtT1 75 kDa fragment
Assay Type: Sandwich
Sensitivity: 0.122 ng/mL
Standard: 20 ng/mL
Detection Range: 0.32-20 ng/mL
Sample Type: tissue homogenates, cell lysates and other biological fluids
Assay Length: 3.5h
Research Area: Endocrinology;
Uniprot ID: Q923E4
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse SIRT1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse SIRT1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse SIRT1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse SIRT1 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
20.00 2.056 1.973
10.00 1.657 1.574
5.00 1.186 1.103
2.50 0.852 0.769
1.25 0.559 0.476
0.63 0.361 0.278
0.32 0.302 0.219
0.00 0.083 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant SIRT1 and the recovery rates were calculated by comparing the measured value to the expected amount of SIRT1 in samples.
Matrix Recovery range Average
serum(n=5) 85-97% 91%
EDTA plasma(n=5) 80-92% 86%
Heparin plasma(n=5) 92-107% 99%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of SIRT1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-98% 92-101% 82-98% 89-97%
EDTA plasma(n=5) 87-101% 87-96% 82-93% 89-97%
Heparin plasma(n=5) 85-93% 98-105% 87-98% 95-102%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
孟津县| 金塔县| 濮阳市| 高安市| 达拉特旗| 五河县| 松桃| 阿坝县| 高唐县| 津南区| 钦州市| 海门市| 屏东市| 十堰市| 鞍山市| 疏勒县| 禹州市| 肃宁县| 兴义市| 五大连池市| 尉犁县| 安达市| 广南县| 达拉特旗| 长宁县| 太仆寺旗| 桑植县| 镇原县| 黎川县| 萨迦县| 娄烦县| 常山县| 萍乡市| 云阳县| 两当县| 吴桥县| 肇源县| 文成县| 临清市| 云梦县| 中方县|