天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產(chǎn)品中心

人組織金屬蛋白酶抑制因子4(TIMP4)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1189
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human TIMP4(Tissue Inhibitors Of Metalloproteinase 4) ELISA Kit
Reactivity: Human
Alternative Names: TIMP Metallopeptidase Inhibitor 4; Tissue Inhibitor of Metalloproteinases 4
Assay Type: Sandwich
Sensitivity: 0.056 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates and other biological fluids.
Assay Length: 3.5h
Research Area: Tumor immunity;Cardiovascular biology;
Uniprot ID: Q99727
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human TIMP4. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human TIMP4. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human TIMP4, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human TIMP4 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線(xiàn)

Concentration (ng/mL) OD Corrected OD
10.00 1.997 1.914
5.00 1.579 1.496
2.50 1.043 0.960
1.25 0.792 0.709
0.63 0.651 0.568
0.32 0.301 0.218
0.16 0.232 0.149
0.00 0.083 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant TIMP4 and the recovery rates were calculated by comparing the measured value to the expected amount of TIMP4 in samples.
Matrix Recovery range Average
serum(n=5) 78-90% 84%
EDTA plasma(n=5) 95-107% 101%
Heparin plasma(n=5) 85-98% 91%

線(xiàn)性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of TIMP4 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 78-92% 83-96% 95-107% 87-102%
EDTA plasma(n=5) 88-102% 86-97% 89-97% 79-95%
Heparin plasma(n=5) 81-94% 96-105% 92-103% 82-96%
關(guān)閉

在線(xiàn)咨詢(xún)

Online consultation

  • 在線(xiàn)咨詢(xún)
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢(xún)

微信掃一掃立即咨詢(xún)

關(guān)閉
德庆县| 永川市| 祥云县| 苍梧县| 永安市| 松江区| 阿合奇县| 德令哈市| 长顺县| 监利县| 乌拉特中旗| 崇明县| 库伦旗| 班戈县| 沂源县| 洪洞县| 绿春县| 宁海县| 永昌县| 渭南市| 安溪县| 永宁县| 东山县| 韩城市| 吕梁市| 阳山县| 家居| 芜湖县| 陆良县| 临江市| 陆川县| 屯门区| 休宁县| 仙桃市| 商洛市| 盐山县| 嵊州市| 通山县| 华池县| 黄大仙区| 康平县|