天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產(chǎn)品中心

人粒細(xì)胞趨化蛋白2(GCP2)酶聯(lián)免疫吸附檢測試劑盒
ELK1104
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview 文獻(xiàn)

Product name: Human GCP2(Granulocyte Chemotactic Protein 2) ELISA Kit
Reactivity: Human
Alternative Names: CXCL6; SCYB6; GCP2; CKA-3; Chemokine(C-X-C-Motif)ligand 6; Small Inducible Cytokine Subfamily B(Cys-X-Cys)Member 6; Chemokine alpha 3; Small-inducible cytokine B6
Assay Type: Sandwich
Sensitivity: 6.5 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Infection immunity;
Uniprot ID: P80162
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human GCP2. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human GCP2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human GCP2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human GCP2 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
1000.00 1.916 1.818
500.00 1.527 1.429
250.00 1.186 1.088
125.00 0.872 0.774
62.50 0.548 0.450
31.25 0.315 0.217
15.63 0.226 0.128
0.00 0.098 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant GCP2 and the recovery rates were calculated by comparing the measured value to the expected amount of GCP2 in samples.
Matrix Recovery range Average
serum(n=5) 80-95% 87%
EDTA plasma(n=5) 85-97% 91%
Heparin plasma(n=5) 96-108% 102%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of GCP2 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-92% 79-96% 95-103% 87-98%
EDTA plasma(n=5) 88-97% 96-103% 86-92% 89-97%
Heparin plasma(n=5) 80-101% 87-96% 96-105% 95-103%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
瑞昌市| 会理县| 双桥区| 泉州市| 中卫市| 宜黄县| 元谋县| 辽宁省| 英山县| 玉溪市| 龙泉市| 县级市| 津南区| 宿迁市| 武隆县| 芷江| 凤冈县| 蒙山县| 临邑县| 巫山县| 上饶市| 来宾市| 张掖市| 台东市| 遵义县| 泗水县| 阳新县| 三门峡市| 盘山县| 隆德县| 贺兰县| 衡山县| 兴城市| 锦州市| 梅河口市| 东台市| 水城县| 平泉县| 天峻县| 龙井市| 密云县|