天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產(chǎn)品中心

人載脂蛋白E(APOE)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1099
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human APOE(Apolipoprotein E) ELISA Kit
Reactivity: Human
Alternative Names: Apo-E; AD2; Apoprotein; Alzheimer Disease 2(E4-Associated,Late Onset
Assay Type: Sandwich
Sensitivity: 1.8 ng/mL
Standard: 300 ng/mL
Detection Range: 4.69-300 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Metabolic pathway;Cardiovascular biology;Hepatology;
Uniprot ID: P02649
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human APOE. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human APOE. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human APOE, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human APOE in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
300.00 1.995 1.882
150.00 1.487 1.374
75.00 0.976 0.863
37.50 0.752 0.639
18.75 0.517 0.404
9.38 0.324 0.211
4.69 0.215 0.102
0.00 0.113 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant APOE and the recovery rates were calculated by comparing the measured value to the expected amount of APOE in samples.
Matrix Recovery range Average
serum(n=5) 80-92% 86%
EDTA plasma(n=5) 83-97% 90%
Heparin plasma(n=5) 86-99% 92%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of APOE and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-102% 83-96% 87-98% 82-95%
EDTA plasma(n=5) 98-106% 86-99% 78-95% 89-97%
Heparin plasma(n=5) 85-94% 87-96% 92-101% 82-98%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
安溪县| 宝清县| 新晃| 乌苏市| 洛隆县| 新田县| 余江县| 清水河县| 兴隆县| 白朗县| 莱阳市| 育儿| 紫云| 大英县| 祁门县| 刚察县| 夏津县| 迁安市| 通江县| 巴林左旗| 黎平县| 晋江市| 临沧市| 平湖市| 榆社县| 宜城市| 门头沟区| 阳东县| 大宁县| 开封市| 普安县| 沁水县| 青州市| 绥德县| 土默特右旗| 宜城市| 金昌市| 赞皇县| 饶河县| 安阳市| 龙门县|