天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產(chǎn)品中心

人S100鈣結(jié)合蛋白A12(S100A12)酶聯(lián)免疫吸附檢測試劑盒
ELK1073
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human S100A12(S100 Calcium Binding Protein A12) ELISA Kit
Reactivity: Human
Alternative Names: CGRP; P6; CAAF1; CAGC; ENRAGE; MRP6; Calgranulin C; Calcium-binding protein in amniotic fluid 1; Extracellular newly identified RAGE-binding; Migration inhibitory factor-related 6
Assay Type: Sandwich
Sensitivity: 31 pg/mL
Standard: 5000 pg/mL
Detection Range: 78.13-5000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;Infection immunity;Immune molecule;
Uniprot ID: P80511
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human S100A12. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human S100A12. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human S100A12, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human S100A12 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
5000.00 2.103 1.985
2500.00 1.755 1.637
1250.00 1.223 1.105
625.00 0.847 0.729
312.50 0.525 0.407
156.25 0.303 0.185
78.13 0.248 0.130
0.00 0.118 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant S100A12 and the recovery rates were calculated by comparing the measured value to the expected amount of S100A12 in samples.
Matrix Recovery range Average
serum(n=5) 82-95% 88%
EDTA plasma(n=5) 89-103% 96%
Heparin plasma(n=5) 78-93% 85%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of S100A12 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-92% 83-96% 78-98% 90-99%
EDTA plasma(n=5) 95-103% 79-92% 97-105% 89-97%
Heparin plasma(n=5) 85-94% 97-106% 82-95% 93-105%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
东丰县| 普兰店市| 方山县| 东宁县| 青田县| 龙口市| 方正县| 四子王旗| 石家庄市| 民丰县| 额尔古纳市| 镇赉县| 疏附县| 普定县| 汤阴县| 延边| 汶川县| 新余市| 鹿泉市| 隆子县| 河南省| 临汾市| 长宁县| 安图县| 柳林县| 河南省| 塔城市| 沭阳县| 封开县| 鄂尔多斯市| 浦县| 汽车| 远安县| 新绛县| 衡阳县| 离岛区| 鹤岗市| 荣成市| 惠水县| 长春市| 郎溪县|