天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產(chǎn)品中心

小鼠降鈣素基因相關肽2(CGRP2)酶聯(lián)免疫吸附檢測試劑盒
ELK1038
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview 文獻

Product name: Mouse CGRP2(Calcitonin Gene Related Peptide 2) ELISA Kit
Reactivity: Mouse
Alternative Names: CALCB; CGRP2; CALC2; CGRP-II; Calcitonin Gene Related Peptide 2; Calcitonin 2; Calcitonin Related Polypeptide Beta
Assay Type: Sandwich
Sensitivity: 4.57 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Infection immunity;Endocrinology;Neuro science;Hormone metabolism;Bone metabolism;Dermatology;
Uniprot ID: Q99JA0
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse CGRP2. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse CGRP2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse CGRP2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse CGRP2 in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (pg/mL) OD Corrected OD
1000.00 2.168 2.110
500.00 1.319 1.261
250.00 0.773 0.715
125.00 0.418 0.360
62.50 0.251 0.193
31.25 0.185 0.127
15.63 0.122 0.064
0.00 0.058 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CGRP2 and the recovery rates were calculated by comparing the measured value to the expected amount of CGRP2 in samples.
Matrix Recovery range Average
serum(n=5) 78-90% 84%
EDTA plasma(n=5) 84-97% 90%
Heparin plasma(n=5) 87-95% 91%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CGRP2 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 83-96% 81-94% 86-98% 92-101%
EDTA plasma(n=5) 85-96% 86-95% 90-102% 81-90%
Heparin plasma(n=5) 87-95% 83-96% 92-102% 82-93%
關閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術支持

關注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關閉
南京市| 莱州市| 三门峡市| 禹城市| 田东县| 兖州市| 长岛县| 依兰县| 海晏县| 沂水县| 文水县| 遂宁市| 喀喇沁旗| 屏边| 黔西县| 芦溪县| 台中县| 兴业县| 盖州市| 米脂县| 安丘市| 木里| 始兴县| 阳泉市| 泸州市| 调兵山市| 同心县| 东海县| 德格县| 凉城县| 钟祥市| 西宁市| 永济市| 日照市| 锦屏县| 西城区| 星子县| 营山县| 静宁县| 新沂市| 沁阳市|