天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產品中心

人細胞間粘附分子1(ICAM1)酶聯(lián)免疫吸附檢測試劑盒
ELK1033
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview 文獻

Product name: Human ICAM1(Intercellular Adhesion Molecule 1) ELISA Kit
Reactivity: Human
Alternative Names: CD54; BB2; P3.58; Human Rhinovirus Receptor; Major group rhinovirus receptor
Assay Type: Sandwich
Sensitivity: 29 pg/mL
Standard: 5000 pg/mL
Detection Range: 78.13-5000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: CD & Adhesion molecule;Tumor immunity;Infection immunity;
Uniprot ID: P05362
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human ICAM1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human ICAM1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human ICAM1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human ICAM1 in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (pg/mL) OD Corrected OD
5000.00 1.861 1.790
2500.00 1.209 1.138
1250.00 0.674 0.603
625.00 0.361 0.290
312.50 0.180 0.109
156.25 0.172 0.101
78.13 0.152 0.081
0.00 0.071 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant ICAM1 and the recovery rates were calculated by comparing the measured value to the expected amount of ICAM1 in samples.
Matrix Recovery range Average
serum(n=5) 84-98% 91%
EDTA plasma(n=5) 79-97% 88%
Heparin plasma(n=5) 80-95% 87%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of ICAM1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-92% 96-104% 90-98% 80-92%
EDTA plasma(n=5) 93-101% 86-92% 81-93% 79-95%
Heparin plasma(n=5) 85-94% 79-96% 98-105% 82-93%
關閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術支持

關注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關閉
阿克| 沅江市| 龙口市| 黄冈市| 浦县| 洪湖市| 鹤壁市| 六安市| 建宁县| 溧阳市| 巴马| 洛浦县| 平南县| 竹山县| 营口市| 望都县| 永仁县| 井冈山市| 光泽县| 河北省| 南川市| 漳州市| 天峻县| 安仁县| 枣强县| 玉林市| 扶余县| 师宗县| 无为县| 武功县| 仪征市| 绥阳县| 鄂伦春自治旗| 滨海县| 甘谷县| 上虞市| 汉源县| 永济市| 通城县| 花莲县| 梨树县|