天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產(chǎn)品中心

大鼠粒細(xì)胞巨噬細(xì)胞集落刺激因子(GMCSF)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1030
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Rat GMCSF(Colony Stimulating Factor 2, Granulocyte Macrophage) ELISA Kit
Reactivity: Rat
Alternative Names: CSF2; GM-CSF; Sargramostim; Molgramostin; Granulocyte-Macrophage Colony Stimulating Factor
Assay Type: Sandwich
Sensitivity: 3 pg/mL
Standard: 500 pg/mL
Detection Range: 7.82-500 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Hematology;
Uniprot ID: P48750
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat GMCSF. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat GMCSF. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat GMCSF, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat GMCSF in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
500.00 2.038 1.957
250.00 1.407 1.326
125.00 0.824 0.743
62.50 0.599 0.518
31.25 0.347 0.266
15.63 0.252 0.171
7.82 0.114 0.033
0.00 0.081 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant GMCSF and the recovery rates were calculated by comparing the measured value to the expected amount of GMCSF in samples.
Matrix Recovery range Average
serum(n=5) 84-97% 90%
EDTA plasma(n=5) 95-107% 101%
Heparin plasma(n=5) 77-95% 86%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of GMCSF and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 95-104% 85-96% 87-102% 91-99%
EDTA plasma(n=5) 78-96% 86-92% 96-105% 89-103%
Heparin plasma(n=5) 85-94% 87-96% 82-90% 92-101%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
比如县| 云林县| 江北区| 莱芜市| 沙河市| 岳池县| 利辛县| 七台河市| 焉耆| 航空| 苍溪县| 神木县| 威宁| 天津市| 沛县| 潼南县| 英山县| 来凤县| 合川市| 红原县| 昭平县| 道孚县| 开平市| 江门市| 名山县| 南京市| 梁山县| 岳西县| 额济纳旗| 泰顺县| 曲阳县| 曲沃县| 嘉黎县| 武隆县| 常德市| 永城市| 老河口市| 武平县| 台州市| 清涧县| 黄梅县|