天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產(chǎn)品中心

人粒細(xì)胞巨噬細(xì)胞集落刺激因子(GMCSF)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1028
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview 文獻(xiàn)

Product name: Human GMCSF(Colony Stimulating Factor 2, Granulocyte Macrophage) ELISA Kit
Reactivity: Human
Alternative Names: CSF2; GM-CSF; Sargramostim; Molgramostin; Granulocyte-Macrophage Colony Stimulating Factor
Assay Type: Sandwich
Sensitivity: 6.5 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Hematology;
Uniprot ID: P04141
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human GMCSF. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human GMCSF. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human GMCSF, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human GMCSF in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
1000.00 1.898 1.827
500.00 1.209 1.138
250.00 0.674 0.603
125.00 0.361 0.290
62.50 0.180 0.109
31.25 0.172 0.101
15.63 0.152 0.081
0.00 0.071 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant GMCSF and the recovery rates were calculated by comparing the measured value to the expected amount of GMCSF in samples.
Matrix Recovery range Average
serum(n=5) 81-96% 88%
EDTA plasma(n=5) 78-94% 86%
Heparin plasma(n=5) 90-103% 96%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of GMCSF and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-92% 89-103% 97-105% 91-99%
EDTA plasma(n=5) 88-102% 86-92% 81-93% 89-104%
Heparin plasma(n=5) 95-104% 79-92% 82-95% 86-97%
關(guān)閉

在線咨詢(xún)

Online consultation

  • 在線咨詢(xún)
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢(xún)

微信掃一掃立即咨詢(xún)

關(guān)閉
宣汉县| 伊宁县| 河池市| 洞口县| 龙口市| 五寨县| 镇宁| 大竹县| 天门市| 准格尔旗| 河西区| 防城港市| 莆田市| 耿马| 嘉鱼县| 灵丘县| 夹江县| 忻州市| 巴东县| 石景山区| 常宁市| 图木舒克市| 宁南县| 克东县| 嵩明县| 乌拉特中旗| 延长县| 东乌珠穆沁旗| 陇南市| 舒兰市| 新野县| 砚山县| 呼图壁县| 桐庐县| 伽师县| 和林格尔县| 阳西县| 永宁县| 齐齐哈尔市| 广宁县| 城口县|