天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產(chǎn)品中心

一步法小鼠25-羥基維生素D(25-OH-D)酶聯(lián)免疫吸附檢測試劑盒
ELK052ES
規(guī)格: 價格:
64T ¥2660.00
112T ¥3800.00

Overview

Product name: EasyStep Mouse 25-OH-D(25 Hydroxy Vitamin D) ELISA Kit
Reactivity: Mouse
Alternative Names: 25 Hydroxy Vitamin D;
Assay Type: Competitive Inhibition
Sensitivity: 7.7 ng/mL
Standard: 5000 ng/mL
Detection Range: 78.13-5000 ng/mL
Sample Type: Serum, plasma
Assay Length: 1.5h
Research Area: Reproductive science;Genetic science;Nutrition metabolism;Bone metabolism;
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Mouse 25-OH-D antigen, and the Mouse 25-OH-D standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells ,then added a HRP-conjugated antibody specific to Mouse 25-OH-D to each microplate well and incubated . After TMB substrate solution is added, the enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ±10nm. The concentration of Mouse 25-OH-D in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
5000.00 0.175
2500.00 0.352
1250.00 0.577
625.00 0.833
312.50 1.152
156.25 1.565
78.13 1.789
0.00 2.132

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant 25-OH-D and the recovery rates were calculated by comparing the measured value to the expected amount of 25-OH-D in samples.
Matrix Recovery range Average
serum(n=5) 95-107% 101%
EDTA plasma(n=5) 82-95% 88%
Heparin plasma(n=5) 78-96% 87%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of 25-OH-D and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 93-102% 81-96% 93-106% 82-95%
EDTA plasma(n=5) 86-97% 83-96% 91-103% 96-105%
Heparin plasma(n=5) 85-100% 80-97% 81-92% 87-103%

產(chǎn)品成分表

關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
桂平市| 栾川县| 抚松县| 缙云县| 绍兴市| 广德县| 辉南县| 玛纳斯县| 民勤县| 拉萨市| 龙川县| 淳安县| 报价| 普兰县| 扎囊县| 林州市| 东乌珠穆沁旗| 华安县| 吕梁市| 剑河县| 云和县| 房山区| 资兴市| 密山市| 鄂托克前旗| 丰原市| 安丘市| 大厂| 宁乡县| 特克斯县| 许昌县| 彭阳县| 庆元县| 仁怀市| 龙川县| 晋宁县| 长治市| 吉首市| 加查县| 辽中县| 巢湖市|