天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產(chǎn)品中心

一步法人血清淀粉樣蛋白A(SAA)酶聯(lián)免疫吸附檢測試劑盒
ELK042ES
規(guī)格: 價格:
64T ¥2240.00
112T ¥3200.00

Overview

Product name: EasyStep Human SAA(Serum Amyloid A) ELISA Kit
Reactivity: Human
Alternative Names: SA-A; SAA1; PIG4; TP53I4; Amyloid protein A; Amyloid fibril protein AA; Serum amyloid A-1 protein
Assay Type: Sandwich
Sensitivity: 0.15 ng/mL
Standard: 50 ng/mL
Detection Range: 0.78-50 ng/mL
Sample Type: Serum, plasma
Assay Length: 1.5h
Research Area: Infection immunity;Kidney biomarker;Hepatology;Urology;
Uniprot ID: P0DJI8
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human SAA, and the Human SAA standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells ,then added a HRP-conjugated antibody specific to Human SAA. After TMB substrate solution is added, only those wells that contain Human SAA and HRP-conjugated antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human SAA in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
50.00 2.035 1.948
25.00 1.643 1.556
12.50 1.073 0.986
6.25 0.892 0.805
3.13 0.518 0.431
1.57 0.365 0.278
0.79 0.208 0.121
0.00 0.087 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant SAA and the recovery rates were calculated by comparing the measured value to the expected amount of SAA in samples.
Matrix Recovery range Average
serum(n=5) 91-99% 95%
EDTA plasma(n=5) 82-95% 88%
Heparin plasma(n=5) 83-98% 91%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of SAA and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 83-95% 85-96% 87-101% 83-95%
EDTA plasma(n=5) 82-94% 85-97% 91-102% 81-90%
Heparin plasma(n=5) 83-97% 92-103% 86-97% 93-101%

產(chǎn)品成分表

關閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術支持

關注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關閉
徐州市| 虞城县| 舟曲县| 潮州市| 翼城县| 泸西县| 奈曼旗| 凤翔县| 青冈县| 乡城县| 东辽县| 汾阳市| 白朗县| 龙海市| 文安县| 赣州市| 四会市| 射洪县| 东乡族自治县| 红桥区| 肥东县| 湘乡市| 德格县| 乐平市| 黄梅县| 雷山县| 蒙自县| 泸州市| 兰州市| 伽师县| 安龙县| 东方市| 三亚市| 凌海市| 富源县| 沈阳市| 丰原市| 甘孜县| SHOW| 南投市| 嘉善县|